Mount Drilling & Water Treatment
Mount Drilling & Water TreatmentMount Drilling & Water Treatment

Residential Water Treatment

line

CSI Alternating Twin Water Softeners are the Cadillac of the softening industry.

Utilizing the Fleck 9000 Control Valve, this versatile model softens water through one resin tankResidential Water Treatment while a second resin tank remains in a stand-by mode. When the integral water meter indicates a need to regenerate, the stand-by tank automatically is put on line to provide uninterrupted soft water while the exhausted resin tank is regenerated. This freshly regenerated tank will then remain in stand-by until the meter triggers another regeneration. Most standard control valves are designed to bypass untreated water to the home during the regeneration cycle. This is why conventional softeners are programmed to regenerate at times of no water usage (usually at night).

Residential Water TreatmentThe Alternating Twin Softener from CSI can regenerate anytime, day or night, without hard water breakthrough. And because soft water is always available, regeneration is accomplished with treated water, keeping the resin bed cleaner than conventional softeners. All units are available with standard 1" riser type distributors or turbulators, which provide a rigorous backwash during regeneration. A bypass valve with 3/4" FNPT Nickel Plated Brass Yoke Connection along with 18" x 33" Brine Tank, Salt Grid Plate, Safety Float, Brine Well and Cap and Safety Overflow Fitting is included as standard equipment. 

Options available include 1" N.P. Brass Yoke Connections, 3/4" and 1" MNPT Plastic Yoke Connections, 18" x 40" Round and 11" x 11" Square Brine Tanks.

Softening capacities range from 24,000 to 96,000 grains with flow rates from 8 gpm to 14 gpm.

 The REACTR™

Residential Water Treatment

CSI Water Treatment Systems reintroduces air injection technology with an innovative new approach for the chemical free treatment of iron, manganese and sulfur gas - The REACTR™. Several new ideas are incorporated in The REACTR™ Water Treatment System. Air injection and free air venting are accomplished through a common manifold assembly which simplifies installation and service. The REACTR™ Manifold Assembly is mounted on a large air mixing tank that triples the amount of air contact and exposure time. A full 1" inlet and outlet is provided to install the REACTR™ Tank between the well pump and pressure tank. This exposes The REACTR™ Tank to full pump flow for increased air draw, air mixing and reduced plugging problems. Oxidized contaminants then enter The REACTR™ Filter where they are removed by The REACTR™ Filter. The REACTR™ Filter is automatically maintained by the Fleck 2510 Control Valve that provides the advantages of adjustable cycle times and high backwash flow capability in a non-brass valve. Bypass Valve, 3/4" Nickel Plated FNPT Yoke Connections and 1" Distributor Tubes are standard equipment. Optional 1" N.P. Brass Yokes, 3/4" and 1" MNPT Plastic Yokes and Dome Fill Holes are available.

The OXYCLEAN™ Automatic Cleansing System is an optional piece of equipment to enhance the operating performance of the REACTR™ System. Situations that are normally tough to handle and require a high level of maintenance can now be solved with the OXYCLEAN™ Cleansing System.

Plugged pipes and fouled media beds can be the result of low levels of iron or sulfur bacteria, tannins and high levels of ferric iron. Many times these situations require a messy, time consuming service call.

Installed in minutes, The OXYCLEAN™ System will automatically inject chlorine during every backwash cycle to clean the entire REACTR™ and associated plumbing.

Every REACTR™ System built has the optional OXYCLEAN™ in mind, installation is easy and can be done during or after installation of the REACTR™ without any changes to the plumbing or electrical wiring.

Residential Water Treatment
 
Residential Water Treatment

CSI Water Treatment Systems reintroduces air injection technology with an innovative new approach for the chemical free treatment of iron, manganese and sulfur gas - The REACTR™. Several new ideas are incorporated in The REACTR™ Water Treatment System. Air injection and free air venting are accomplished through a common manifold assembly which simplifies installation and service. The REACTR™ Manifold Assembly is mounted on a large air mixing tank that triples the amount of air contact and exposure time. A full 1" inlet and outlet is provided to install the REACTR™ Tank between the well pump and pressure tank. This exposes The REACTR™ Tank to full pump flow for increased air draw, air mixing and reduced plugging problems. Oxidized contaminants then enter The REACTR™ Filter where they are removed by The REACTR™ Filter. The REACTR™ Filter is automatically maintained by the Fleck 2510 Control Valve that provides the advantages of adjustable cycle times and high backwash flow capability in a non-brass valve. Bypass Valve, 3/4" Nickel Plated FNPT Yoke Connections and 1" Distributor Tubes are standard equipment. Optional 1" N.P. Brass Yokes, 3/4" and 1" MNPT Plastic Yokes and Dome Fill Holes are available.

The OXYCLEAN™ Automatic Cleansing System is an optional piece of equipment to enhance the operating performance of the REACTR™ System. Situations that are normally tough to handle and require a high level of maintenance can now be solved with the OXYCLEAN™ Cleansing System.

Plugged pipes and fouled media beds can be the result of low levels of iron or sulfur bacteria, tannins and high levels of ferric iron. Many times these situations require a messy, time consuming service call.

Residential Water Treatment

Installed in minutes, The OXYCLEAN™ System will automatically inject chlorine during every backwash cycle to clean the entire REACTR™ and associated plumbing.

Every REACTR™ System built has the optional OXYCLEAN™ in mind, installation is easy and can be done during or after installation of the REACTR™ without any changes to the plumbing or electrical wiring.

Send mail
 
Services
grade
dthrotarydrilling.com 
 
Home | About us | Subscribe | Advertise in Magazine | Board | Technical Papers | Interview | E-Paper | Editor's Desk | Media Kit | Directory | Contact Us | Site Map

Terms & Conditions - Disclaimer Copyright © 2009 dthrotarydrilling.com All rights reserved.